Industries · Technology · Featured · Studies

Wireless Synthetic Telepathy and Neurotechnology: A Study of Neural Decoding and Communication

Wireless Synthetic Telepathy and Neurotechnology: A Study of Neural Decoding and Communication publication cover

Neural measurement, statistical inference and the limits of brain-mediated communication

Abstract

Brain–computer interfaces can translate recorded activity into selections and movement commands, and experimental work is beginning to relate neural signals more directly to speech and perceptual content. These achievements do not make “synthetic telepathy” a single established capability. This study separates physical acquisition, statistical inference, digital transmission, sensory feedback and authorised communication. Evidence includes EEG spelling and cursor control, implanted motor interfaces, a wireless vowel synthesiser, prompted imagined-word classification and scanner-based prediction or reconstruction of viewed material. The distinction between a constrained task and unrestricted cognition is decisive: a selected letter, a classified phonetic component and a reconstructed image are different outcomes. Wireless telemetry transports measurements already obtained by an interface; it does not remove the need for that interface. Reconstruction also depends on the task and the model’s prior information, so an output cannot automatically be attributed wholly to the participant. A proposed validation programme tests independent performance, artefacts, practical communication benefit and user control. Established research-ethics principles support consent and confidentiality without presupposing unproven surveillance capabilities. The immediate opportunities concern assistive communication and dependable human–machine systems; stronger claims require separate, reproducible evidence.

Contents

Research orientation

The study proceeds from physical measurement to empirical decoding, causal interpretation and proposed validation. Governance and human factors are treated as conditions of useful communication, with the evidence boundaries collected in Appendix A.

1 Research question and intellectual scope

What would it mean for a person to communicate without ordinary speech or hand movement? An engineering answer must identify what is measured, how a message is selected, how it is transmitted and how the recipient interprets it. “Synthetic telepathy” can be a metaphor for that ambition, but it does not identify a mechanism. The scientific question is whether a defined channel carries information attributable to a consenting user, with an error rate and practical burden that make it useful.

This study distinguishes five operations: recording a physiological signal, inferring a task variable, transporting data, supplying feedback and communicating an intended message. These operations can be combined, but success at one does not establish success at every other. A radio link can carry an erroneous classification perfectly. A classifier can recognise a trained movement without representing the meaning of a sentence. A person can receive a sensory cue without receiving another person’s private experience.

A thought is not one engineering variable. Attending to a displayed letter, attempting a movement, repeating an imagined word and considering a personal belief have different observable consequences and different possible ground truths. “Decoding” must therefore specify its target. Selection among a small set of alternatives cannot be reported as free-form conversation, and recognition of viewed material cannot be assumed to reveal unprompted imagination.

The practical objective is communication that people can initiate, correct and stop. Scientific interest in information present in neural activity does not automatically authorise its collection or interpretation for other purposes. The account below considers both the opportunities for severe motor impairment and the risks of assigning unwarranted meaning to uncertain measurements. It offers a critical synthesis and proposed tests, not proprietary experimental results or findings about covert deployment.

2 Evidence selection and analytical method

The evidence is selected to distinguish measurement modalities and the kinds of inference each permits. Original reports of EEG, cortical recording, wireless telemetry, fMRI encoding and sensory feedback are considered alongside methodological investigations and original ethics instruments. This is a structured critical synthesis, not an exhaustive systematic review or a pooled estimate of clinical effectiveness. No new participant data have been collected.

For each experiment, the relevant record includes the population, apparatus, task, training information, test conditions and outcome. Where only an original abstract is available, interpretation is limited accordingly. Clinical feasibility, offline classification, closed-loop control and independent everyday use are assessed separately. A demonstration in one implanted participant can establish feasibility while leaving population reliability and clinical effectiveness unsettled.

Reported performance is meaningful only with its denominator. Selecting the right target, discriminating a vowel, ranking a candidate image and producing an understood message are not interchangeable accuracy measures. The comparison must also include calibration, failed selections, corrections and opportunities when the user wished to remain silent. A useful system need not maximise every laboratory score; it must perform the task its user actually needs.

Kriegeskorte et al. (2009) show how selecting measurements and testing them on the same data can create apparently informative results even from noise. That problem is directly relevant to large neural datasets with many possible features. The analytical standard adopted here is independence between model selection and final evaluation, with the unit of independence chosen to match the claim. Many samples from one recording do not establish performance in many people.

3 Measurement, interfaces and communication primitives

Scalp electroencephalography measures voltage differences; magnetoencephalography measures magnetic fields associated with neural currents; cortical electrodes acquire electrical activity close to neural tissue; fMRI measures a haemodynamic response. These observation processes differ in their spatial coverage, timing, invasiveness and susceptibility to disturbance. They do not provide interchangeable transcripts of cognition.

Logothetis et al. (2001) compared intracortical recordings with fMRI in monkey visual cortex. Their results related the blood-oxygen-level-dependent signal to local neural processing, with important variation between recording sites and animals. The methodological implication is that BOLD is an indirect physiological observation. A decoder must accommodate the relation between the target process and that observation; it cannot treat each image as an instantaneous record of individual neuronal messages.

Cohen (1972) demonstrated measurement of brain magnetic activity using a sensitive superconducting magnetometer in a heavily shielded room. This establishes a physical measurement method, not semantic reception at arbitrary distance. “Non-invasive” describes how the sensor interacts with the body; it does not mean that no sensor, environmental control or signal-processing assumptions are required.

Table 1. Distinct operations within a neural communication system
OperationEvidence requiredInference that does not follow
RecordingA physiological signal and an account of artefacts.Automatic knowledge of its cognitive meaning.
DecodingIndependent prediction of a specified target.Transfer to every task, person or setting.
Wireless transportReliable carriage of acquired measurements.Remote acquisition from an uninstrumented brain.
FeedbackA reproducible, defined percept or task cue.Insertion of arbitrary beliefs or experiences.
CommunicationA message understood and authorised in a protocol.An unrestricted channel between minds.

Chestek et al. (2009) make the recording–transport distinction concrete. Their HermesC system transmitted neural data obtained from electrode arrays implanted in freely moving rhesus macaques. Removing a cable allowed observation in a less constrained setting. The transmitter did not discover brain activity at the receiver’s range: electrodes had already acquired the signal. Consequently, a wireless specification says nothing by itself about semantic accuracy or the possibility of recording from someone without an interface.

The whole system must be evaluated as a chain. Signal quality can deteriorate before transmission, a classifier can be miscalibrated despite a clean recording, and a correctly selected symbol can be misunderstood after delivery. Recording, inference and use therefore need separate failure records. Otherwise an improvement in one component can conceal a limitation elsewhere.

4 Empirical evidence for neural decoding

Intentional selection and movement control

Farwell and Donchin (1988) developed a spelling interface using the P300 event-related response as participants attended to characters in a structured display. The neural response supported selection within a known protocol. The selected character became a message through the user’s attention and the interface’s rules; the experiment did not identify an unrestricted thought independently of that protocol.

Birbaumer et al. (1999) described a spelling device based on trained control of slow cortical potentials in people with severe paralysis. This illustrates a different route to communication: learning to modulate a usable control signal rather than directly recovering the semantic content of spontaneous thought. A channel can have substantial personal value even when its selections are slow and deliberate.

Wolpaw and McFarland (2004) demonstrated two-dimensional cursor control using scalp EEG and an adaptive algorithm, including people with spinal cord injury. This was evidence that non-invasive signals could support more than a single binary selection in trained users. It did not show that such a channel was immediately available to every person or that cursor performance measured language understanding.

Hochberg et al. (2006) demonstrated external-device control using movement-related activity recorded from an implanted array in a person with tetraplegia. The result linked intended movement to an assistive output despite disrupted bodily movement. Its importance is functional access to a preserved signal, while its interpretation remains tied to the participant, implant and tested tasks.

Simeral et al. (2011) tested point-and-click control on five prospectively selected consecutive days, 1000 days after implantation in a participant with tetraplegia. Useful neural signals remained available and supported repeatable performance with daily preparation of the decoder. The interval since surgery is an encouraging longevity observation, but it is not a demonstration of uninterrupted, independently maintained use throughout all 1000 days.

Speech-related signals and their present limits

Guenther et al. (2009) reported an implanted speech-related interface in one volunteer with locked-in syndrome. Recorded signals were transmitted wirelessly and used to control acoustic parameters of a synthesiser, with immediate auditory feedback. In a three-vowel task, the reported average hit rate rose from 45% to 70% with practice. This was a meaningful closed-loop speech-motor result. It was not 70% word accuracy in unrestricted conversation, and the prospect of conversational synthesis remained a research objective.

Pei et al. (2011) examined vowels and consonant pairs in visually prompted spoken and imagined words using temporary cortical-surface recordings in people undergoing epilepsy evaluation. Eight participants performed overt repetition and six performed the covert task. Their offline analyses reported discrimination of phonetic components, with performance varying across people and recording locations. The result is relevant to imagined-speech interfaces, but does not establish spontaneous sentence transcription. Repeated prompted words, a small set of alternatives and selected recording locations differ substantially from an independently validated, continuously available communication aid.

Viewed material, semantic features and reconstruction

Kay et al. (2008) fitted models relating natural-image features to fMRI responses in visual cortex. The models could identify which novel image an observer had viewed from a candidate set. Generalisation to new images is more informative than memorising responses to the training pictures. Nevertheless, candidate identification depends on the alternatives supplied; it is a different task from reconstructing an arbitrary image with no candidate information.

Mitchell et al. (2008) combined text-derived semantic features with fMRI recordings associated with concrete nouns. The model predicted activation patterns for words omitted from training and was evaluated using the available set of 60 nouns. This is evidence for a model connecting semantic features with measured brain responses. It is not an open-ended transcript of private inner speech: the vocabulary, stimulus task and predicted neural representation define the result.

Nishimoto et al. (2011), published online on 22 September, extended the visual problem to natural movies. They combined fitted fMRI encoding models with a sampled natural-movie prior to reconstruct aspects of viewed clips. The output was constrained by both the measured responses and available candidate movie structure. A visually compelling reconstruction therefore cannot be assumed to reproduce every detail of a person’s experience. The experiment addresses viewing under scanner conditions, not dreams, autobiographical memories or unobserved thought in everyday settings.

Table 2. Why the experimental task matters
DemonstrationSupported achievementUnresolved extension
EEG and implanted cursor interfacesIntentional selections or movement control.Reliable communication for every prospective user.
Guenther et al. (2009)Closed-loop control of a vowel synthesiser.Unrestricted conversational speech.
Pei et al. (2011)Offline prompted phonetic classification.Independent continuous imagined-sentence decoding.
Kay, Mitchell and Nishimoto studiesConstrained prediction, identification or reconstruction.A general transcript of private experience.

5 Causal analysis of decoding and communication

Separating neural information from prior expectations

A conceptual description is P(message | recording, context) ∝ P(recording | message, context) × P(message | context). This is Bayes’ rule applied to a proposed inference problem, not a validated LupoToro decoder. It separates how well a candidate message predicts the recording from how plausible the message already was given the task. A familiar word or image can be favoured partly because the candidate set or prior makes it likely.

For an assistive interface, constraints can be beneficial: narrowing choices can reduce errors and effort. For a claim about what someone privately thought, the same constraint creates an attribution problem. Evaluation should establish the additional information supplied by the real recording relative to a context-only baseline. A reconstruction that remains persuasive after the recording is replaced with a mismatched one would require a different explanation from accurate signal-specific inference.

Poldrack (2006) analyses the related problem of reverse inference. A brain region’s involvement in a task does not make that task the unique explanation of its activity. The evidential value depends on how selectively the activity relates to the proposed process and on prior probabilities. It follows that a broad signal associated with effort or attention cannot by itself identify a particular belief, deception or intention.

Feedback is a learned input, not transferred meaning

O’Doherty et al. (2009) investigated stimulation-mediated task cues in macaques operating a brain–machine interface. The findings supported useful feedback in one of the tested preparations, with different results across stimulation sites. Such evidence concerns learned task information and an instrumented animal model. It does not demonstrate the delivery of arbitrary meanings, memories or another individual’s experience.

A proposed system joining one person’s BCI output to another person’s sensory display would contain an ordinary communication channel and an agreed code. Adding a neural feedback component would add another interface requiring independent validation. The experiments examined here do not establish an unmediated transfer between human minds. Any future cooperative demonstration should compare its benefit and burden with a simpler channel carrying the same message.

Foster and Finch (1974) provide a separate mechanistic example: microwave energy can generate an acoustic disturbance through thermal expansion. An induced auditory input is not a reverse channel that reads neural content. Conflating sensory stimulation with measurement obscures the direction of information flow and does not supply evidence for remote semantic surveillance.

6 Constraints, alternative explanations and unsupported extrapolations

A successful prediction need not obtain its information by the intended route. Eye movements, facial muscle activity, an audible response, stimulus order or an equipment artefact may correlate with the target. If those variables predict the class, an algorithm can exploit them without identifying the claimed neural process. Such a signal might still be useful for an assistive device, but the description of its mechanism would need to change.

McMenamin et al. (2010) experimentally varied neural and muscle activity while assessing EEG correction methods. Their results showed that muscle contamination can distort scalp and source-space estimates and that independent-component correction does not guarantee complete separation. The practical inference is to validate artefact handling against relevant observations, rather than equate a component labelled “neural” with a proven neural source.

Generalisation has several dimensions: new examples, new sessions, different people, changing physiology and environments outside the laboratory. Evidence for one is not evidence for all. A decoder can identify a novel image while retaining dependence on a familiar observer’s calibrated scanner responses. A successful within-session experiment may leave future-session reliability uncertain. These are design questions to investigate, not reasons to dismiss a useful feasibility result.

Claims of unrestricted remote neural monitoring add unverified steps: acquiring a sufficiently specific signal from an uninstrumented person, separating it from environmental sources, mapping it to meaning and maintaining independent performance across people and situations. The studies reviewed here do not establish that chain. A patent, funding proposal or suggestive name cannot replace a reproducible evaluation of the asserted capability.

The conclusion is evidential. It does not require a claim that every imaginable future measurement method is impossible. It requires that demonstrated interfaces be described according to what they measured and that additional capabilities remain hypotheses until tested. Reports of unusual experiences alone cannot determine a transmission mechanism, prove that a decoder exists or identify a responsible actor.

7 Falsifiable validation and privacy research

The following programme is proposed work, not a report of completed experiments. Its objective is useful communication in consenting, instrumented settings. Non-invasive tasks and ethically obtained existing records can address many inferential questions. Invasive recording or stimulation requires a separately justified clinical or research programme; no intervention is warranted merely to make a speculative capability appear dramatic.

Table 3. Proposed validation questions
ClaimComparisonDecision-relevant outcome
Recordings add target informationAuthentic recordings versus context-only and nuisance-signal baselines.Independent improvement attributable to the intended signal.
Performance survives calibrationSeparate sessions, with a fixed final evaluation.Errors, uncertainty and retraining burden.
The user controls outputAuthorised selections versus consented periods without selection.False activation, missed intention and usable cancellation.
The interface helps communicationThe user’s available alternative communication method.Understood messages, correction effort, fatigue and preference.
A more elaborate channel adds valueA simpler channel carrying the same agreed information.Benefit after setup, delay and error costs.

The split between development and evaluation should follow the intended claim. New-user performance requires people excluded from all model selection. Future-session performance requires separate sessions. Preprocessing and feature selection must be fitted within development data, leaving the final evaluation untouched. Confidence intervals should reflect the independent units of observation; a dense time series cannot manufacture a large clinical population.

Primary endpoints, exclusions and stopping rules should be specified before the decisive evaluation. Exploratory analyses can identify new hypotheses, but their apparent success needs a fresh test. Appropriate control data should preserve ordinary dependencies in the recordings, so that the comparison does not make the real task artificially easy. Failed sessions, omitted participants and correction effort should be reported alongside successful examples.

Communication quality includes message fidelity, time to a usable message, availability, false starts and the effort needed to reverse an error. The intended target should be independently recorded where feasible. Asking a participant to endorse an ambiguous machine output after seeing it is weaker evidence than testing a prespecified message. For a genuinely private and unobservable mental event, the absence of independent ground truth remains an important limitation.

Privacy tests should use non-sensitive, consented tasks. A proposed interface should distinguish a candidate selection from a message the user has accepted, and should provide a practical means to pause recording or cancel output. Those are design requirements motivated by uncertainty and autonomy. They do not depend on assuming that a general-purpose private-thought decoder has already been demonstrated.

8 Defence adjacent implications and governance

The strongest immediate defence relevance is assistive rehabilitation and dependable interaction for personnel with impaired movement or speech. An institution’s interest in a technology does not change what an experiment establishes. A neural selection system remains limited by its recording apparatus, training, tested population and outcome. Describing it as an intelligence capability would require evidence for that different use.

The Belmont Report (National Commission, 1979) provides principles of respect for persons, beneficence and justice, with attention to informed consent, risk–benefit assessment and participant selection. Applied to neural-interface research, these principles support explaining both the intervention and what may be inferred from the resulting data. Clinical care should not be confused with an experimental promise of benefit.

UNESCO’s Universal Declaration on Bioethics and Human Rights (2005) addresses consent, privacy, confidentiality and vulnerability in medicine, life sciences and associated technologies. It supplies a relevant ethical framework, not approval of a neural device or a uniform domestic rule governing every application. The proposal here is to incorporate those principles into study design and data access before any institutional deployment.

Consent needs particular care in military, employment or other hierarchical settings. Permission to operate a communication aid should not automatically authorise secondary inference about loyalty, productivity or personal beliefs. Withdrawal should have a practical alternative, and responsibility for clinical care, research and operational assessment should be explicit. These are proposed safeguards for real data practices, rather than claims about undisclosed surveillance machinery.

Procurement should require a clear record of the population tested, target inferred, apparatus, calibration, error distribution and authorised purpose. A classifier trained for a task should not be repurposed as a diagnostic or disciplinary instrument without separate evidence. Human review cannot correct this problem if reviewers are simply shown a confident label without its underlying limitations.

9 Aerospace, human factors and communication infrastructure

For aerospace applications, laboratory classification is only one part of a reliable human–machine system. The relevant question is whether an additional interface improves a defined task while preserving operator understanding and control. Preparation, distracting alerts, misclassification and failure recovery belong in the comparison. A neural measurement is not automatically a better control input because it is closer to the nervous system.

Parasuraman, Sheridan and Wickens (2000) distinguish automation of information acquisition, analysis, decision selection and action. Their framework explains why automating one stage changes the demands placed on the operator rather than simply removing work. Applied here, interpreting a physiological signal and allowing it to trigger an action are separate design decisions. The consequences of a false interpretation must be evaluated at the level of the whole task.

A suitable proposed next step is simulator comparison of an adaptive interface with a conventional design, using consented participation and independently measured performance. False alarms, missed events, unnecessary interventions and workload should accompany classifier accuracy. The evaluation should distinguish a change in the operator from a fault in the sensor or environment, because these require different responses.

For assistive users, infrastructure includes fitting, calibration, maintenance, repair and continuity of support. A precise laboratory decoder with frequent downtime may provide less independence than a slower dependable method. An alternative means of communication should remain available. Software changes that alter the mapping from signals to selections should be evaluated before their output is attributed to the user.

The interface should preserve the distinction between a recorded signal, a machine-generated candidate and an accepted message. A recipient needs to know when correction is pending. This is an ordinary communication-design requirement with particular importance when the user cannot quickly interrupt a mistaken output through speech or movement.

10 Interpretation and research priorities

The evidence supports specific forms of progress: intentional EEG selection, implanted movement control, experimental vowel synthesis, prompted phonetic classification and constrained inference from scanner measurements. These achievements depend on a physical interface, a defined task and an inference procedure. Their value does not require describing them as unrestricted telepathy.

The central scientific distinction is between information measured in the nervous system and information supplied by the experiment’s structure. Both may contribute to a useful communication aid. They must nevertheless be separated when evaluating a claim about what someone thought. Prediction can succeed without identifying a unique cause, and a plausible reconstruction can include details favoured by its prior.

Research priorities should therefore concern independent validation, transfer to new sessions and users, practical communication benefit and reliable control of output. Evidence involving imagined speech makes careful data governance relevant even within constrained experiments; it does not establish universal access to private cognition. Consent and confidentiality should develop alongside empirical capability rather than wait for stronger speculative claims to be resolved.

A defensible programme needs a specified signal, a falsifiable inference, an appropriate comparator and a person who controls what is conveyed. A proposed connection between neural interfaces must meet those requirements at every stage. That provides a useful basis for assistive research, engineering assessment and public understanding without inventing a capability beyond the evidence.

Appendix A Evidence and inference audit

This audit distinguishes experimental outcomes from extensions that would require new evidence. It is an analytical summary, not an additional dataset or a certification of any product.

Table 4. Evidence and inference audit
Evidence classSupported inferenceSeparate demonstration required
Spelling and movement interfacesTask-related recorded activity can supply intentional selections.Dependable benefit across the intended clinical population.
Speech-related cortical studiesRestricted synthesis or prompted phonetic discrimination is feasible.Independent continuous communication of novel sentences.
fMRI prediction and reconstructionViewed or prompted content constrains measured responses.Unrestricted recovery of unobserved private thought.
Wireless implanted recordingAcquired data can be transported without an external signal cable.Sensor-free acquisition at a distance.
Stimulation-mediated animal cuesA learned task can use instrumented feedback.Transfer of arbitrary semantic content between human minds.

No proprietary observations, unreported participant outcomes or proof of physical impossibility is asserted. The proposed tests are intended to make the missing evidence explicit. An honest result should identify the task solved, the apparatus required, the uncertainty remaining and the additional observations that would change the assessment.

References

Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E. and Flor, H. (1999) ‘A spelling device for the paralysed’, Nature, 398, pp. 297–298. https://doi.org/10.1038/18581.

Chestek, C.A., Gilja, V., Nuyujukian, P., Kier, R.J., Solzbacher, F., Ryu, S.I., Harrison, R.R. and Shenoy, K.V. (2009) ‘HermesC: low-power wireless neural recording system for freely moving primates’, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 17(4), pp. 330–338. https://doi.org/10.1109/TNSRE.2009.2023293.

Cohen, D. (1972) ‘Magnetoencephalography: detection of the brain’s electrical activity with a superconducting magnetometer’, Science, 175(4022), pp. 664–666. https://doi.org/10.1126/science.175.4022.664.

Farwell, L.A. and Donchin, E. (1988) ‘Talking off the top of your head: toward a mental prosthesis utilizing event-related brain potentials’, Electroencephalography and Clinical Neurophysiology, 70(6), pp. 510–523. https://doi.org/10.1016/0013-4694(88)90149-6.

Foster, K.R. and Finch, E.D. (1974) ‘Microwave hearing: evidence for thermoacoustic auditory stimulation by pulsed microwaves’, Science, 185(4147), pp. 256–258. https://doi.org/10.1126/science.185.4147.256.

Guenther, F.H., Brumberg, J.S., Wright, E.J., Nieto-Castanon, A., Tourville, J.A., Panko, M., Law, R., Siebert, S.A., Bartels, J.L., Andreasen, D.S., Ehirim, P., Mao, H. and Kennedy, P.R. (2009) ‘A wireless brain-machine interface for real-time speech synthesis’, PLOS ONE, 4(12), e8218. https://doi.org/10.1371/journal.pone.0008218.

Hochberg, L.R., Serruya, M.D., Friehs, G.M., Mukand, J.A., Saleh, M., Caplan, A.H., Branner, A., Chen, D., Penn, R.D. and Donoghue, J.P. (2006) ‘Neuronal ensemble control of prosthetic devices by a human with tetraplegia’, Nature, 442, pp. 164–171. https://doi.org/10.1038/nature04970.

Kay, K.N., Naselaris, T., Prenger, R.J. and Gallant, J.L. (2008) ‘Identifying natural images from human brain activity’, Nature, 452, pp. 352–355. https://doi.org/10.1038/nature06713.

Kriegeskorte, N., Simmons, W.K., Bellgowan, P.S.F. and Baker, C.I. (2009) ‘Circular analysis in systems neuroscience: the dangers of double dipping’, Nature Neuroscience, 12(5), pp. 535–540. https://doi.org/10.1038/nn.2303.

Logothetis, N.K., Pauls, J., Augath, M., Trinath, T. and Oeltermann, A. (2001) ‘Neurophysiological investigation of the basis of the fMRI signal’, Nature, 412, pp. 150–157. https://doi.org/10.1038/35084005.

McMenamin, B.W., Shackman, A.J., Maxwell, J.S., Bachhuber, D.R.W., Koppenhaver, A.M., Greischar, L.L. and Davidson, R.J. (2010) ‘Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG’, NeuroImage, 49(3), pp. 2416–2432. https://doi.org/10.1016/j.neuroimage.2009.10.010.

Mitchell, T.M., Shinkareva, S.V., Carlson, A., Chang, K.-M., Malave, V.L., Mason, R.A. and Just, M.A. (2008) ‘Predicting human brain activity associated with the meanings of nouns’, Science, 320(5880), pp. 1191–1195. https://doi.org/10.1126/science.1152876.

National Commission for the Protection of Human Subjects of Biomedical and Behavioral Research (1979) The Belmont Report: Ethical Principles and Guidelines for the Protection of Human Subjects of Research. Federal Register, 44(76), pp. 23192–23197, 18 April. https://www.hhs.gov/ohrp/regulations-and-policy/belmont-report/read-the-belmont-report/index.html.

Nishimoto, S., Vu, A.T., Naselaris, T., Benjamini, Y., Yu, B. and Gallant, J.L. (2011) ‘Reconstructing visual experiences from brain activity evoked by natural movies’, Current Biology, advance online publication, 22 September. https://doi.org/10.1016/j.cub.2011.08.031.

O’Doherty, J.E., Lebedev, M.A., Hanson, T.L., Fitzsimmons, N.A. and Nicolelis, M.A.L. (2009) ‘A brain-machine interface instructed by direct intracortical microstimulation’, Frontiers in Integrative Neuroscience, 3, article 20. https://doi.org/10.3389/neuro.07.020.2009.

Parasuraman, R., Sheridan, T.B. and Wickens, C.D. (2000) ‘A model for types and levels of human interaction with automation’, IEEE Transactions on Systems, Man, and Cybernetics — Part A: Systems and Humans, 30(3), pp. 286–297. https://doi.org/10.1109/3468.844354.

Pei, X., Barbour, D.L., Leuthardt, E.C. and Schalk, G. (2011) ‘Decoding vowels and consonants in spoken and imagined words using electrocorticographic signals in humans’, Journal of Neural Engineering, 8(4), 046028. https://doi.org/10.1088/1741-2560/8/4/046028.

Poldrack, R.A. (2006) ‘Can cognitive processes be inferred from neuroimaging data?’, Trends in Cognitive Sciences, 10(2), pp. 59–63. https://doi.org/10.1016/j.tics.2005.12.004.

Simeral, J.D., Kim, S.-P., Black, M.J., Donoghue, J.P. and Hochberg, L.R. (2011) ‘Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array’, Journal of Neural Engineering, 8(2), 025027. https://doi.org/10.1088/1741-2560/8/2/025027.

United Nations Educational, Scientific and Cultural Organization (UNESCO) (2005) Universal Declaration on Bioethics and Human Rights. Adopted by the General Conference, Paris, 19 October. https://www.unesco.org/en/legal-affairs/universal-declaration-bioethics-and-human-rights.

Wolpaw, J.R. and McFarland, D.J. (2004) ‘Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans’, Proceedings of the National Academy of Sciences, 101(51), pp. 17849–17854. https://doi.org/10.1073/pnas.0403504101.